#smallshaker Tag

20N and 100N  All-In-One Shakers with integrated amplifier and signal generator   20N and 100N permanent magnet and modal shakers have integrated signal generator that generate Sinus signals from 1 Hz to 15,000 Hz. With the sine generator the frequency can be adjusted manually. These 4 models (PM-20, MS-20, PM-100, MS-100) have a  LED screen which shows the internally generated sinus signal frequency. By having integrated amplifiers, these shakers...

Read More

/*! elementor - v3.6.7 - 03-07-2022 */ .elementor-heading-title{padding:0;margin:0;line-height:1}.elementor-widget-heading .elementor-heading-title[class*=elementor-size-]>a{color:inherit;font-size:inherit;line-height:inherit}.elementor-widget-heading .elementor-heading-title.elementor-size-small{font-size:15px}.elementor-widget-heading .elementor-heading-title.elementor-size-medium{font-size:19px}.elementor-widget-heading .elementor-heading-title.elementor-size-large{font-size:29px}.elementor-widget-heading .elementor-heading-title.elementor-size-xl{font-size:39px}.elementor-widget-heading .elementor-heading-title.elementor-size-xxl{font-size:59px}Inertial Electrodynamic shakers /*! elementor - v3.6.7 - 03-07-2022 */ .e-container.e-container--row .elementor-spacer-inner{width:var(--spacer-size)}.e-container.e-container--column .elementor-spacer-inner,.elementor-column .elementor-spacer-inner{height:var(--spacer-size)} Inertial electrodynamic shaker is very similar to the voice coil which is used in speakers. /*! elementor - v3.6.7 - 03-07-2022 */ .elementor-widget-image{text-align:center}.elementor-widget-image a{display:inline-block}.elementor-widget-image a img[src$=".svg"]{width:48px}.elementor-widget-image img{vertical-align:middle;display:inline-block} Figure 1: Voice coil cross section Voice coils work according to the Newton’s second law: F=ma       ...

Read More

Our latest innovation: Compact and Lightweight Electrodynamic PM-10 Shaker.  The magnetic field used in this shaker is a permanent magnet. This permanent magnet shaker has a force rating  of up to 10N and a frequency range of 10-10,000Hz. An external amplifier (SA-150) is used to drive the PM-10 shaker. PM shakers are commonly used in various industries for product testing, product development, quality control, research & development...

Read More

Articles

/*! elementor - v3.12.2 - 23-04-2023 */ .elementor-widget-image{text-align:center}.elementor-widget-image a{display:inline-block}.elementor-widget-image a img[src$=".svg"]{width:48px}.elementor-widget-image img{vertical-align:middle;display:inline-block} /*! elementor - v3.12.2 - 23-04-2023 */ .elementor-heading-title{padding:0;margin:0;line-height:1}.elementor-widget-heading .elementor-heading-title[class*=elementor-size-]>a{color:inherit;font-size:inherit;line-height:inherit}.elementor-widget-heading .elementor-heading-title.elementor-size-small{font-size:15px}.elementor-widget-heading .elementor-heading-title.elementor-size-medium{font-size:19px}.elementor-widget-heading .elementor-heading-title.elementor-size-large{font-size:29px}.elementor-widget-heading .elementor-heading-title.elementor-size-xl{font-size:39px}.elementor-widget-heading .elementor-heading-title.elementor-size-xxl{font-size:59px}Electrodynamic Shakers & Accessories Modal Test & Modal Analysis Shaker Selection /*! elementor - v3.12.2 - 23-04-2023 */ .elementor-column .elementor-spacer-inner{height:var(--spacer-size)}.e-con{--container-widget-width:100%}.e-con-inner>.elementor-widget-spacer,.e-con>.elementor-widget-spacer{width:var(--container-widget-width,var(--spacer-size));--align-self:var(--container-widget-align-self,initial);--flex-shrink:0}.e-con-inner>.elementor-widget-spacer>.elementor-widget-container,.e-con-inner>.elementor-widget-spacer>.elementor-widget-container>.elementor-spacer,.e-con>.elementor-widget-spacer>.elementor-widget-container,.e-con>.elementor-widget-spacer>.elementor-widget-container>.elementor-spacer{height:100%}.e-con-inner>.elementor-widget-spacer>.elementor-widget-container>.elementor-spacer>.elementor-spacer-inner,.e-con>.elementor-widget-spacer>.elementor-widget-container>.elementor-spacer>.elementor-spacer-inner{height:var(--container-widget-height,var(--spacer-size))} Inertial Shaker Working Principle Sensor Selection Vibration Shakers in Aerospace...

Read More

/*! elementor - v3.12.2 - 23-04-2023 */ .elementor-widget-image{text-align:center}.elementor-widget-image a{display:inline-block}.elementor-widget-image a img[src$=".svg"]{width:48px}.elementor-widget-image img{vertical-align:middle;display:inline-block} Standard shaker tests can be driven at different frequencies and amplitudes. For these tests, the specimen can be attached directly to the shaker armature and the vibrating surface can be increased by using a head expander to suit the specimen size. Vertical excitation can be converted to horizontal excitation by using a slip table. In...

Read More

Electrodynamic shakers can be in different shapes, such as standard shakers, modal shakers or inertial shakers. Depending on the area of use, one of these shaker types must be selected for the test. Standard Shakers (PM Shaker)Tests with standard shaker can be driven at different frequencies and amplitudes. In these tests the test specimen can be directly fixed to the shaker armature and vibrating surface area...

Read More